{"id":20771,"date":"2023-09-22T14:25:39","date_gmt":"2023-09-22T12:25:39","guid":{"rendered":"https:\/\/beta.cybus.io\/resources\/glossar\/ansible-2-2-2-2-2-2-2-2-2-2-2-2-2-2-2-2-2-2-2\/"},"modified":"2026-11-18T20:14:39","modified_gmt":"2026-11-18T19:14:39","slug":"opc-ua","status":"publish","type":"page","link":"https:\/\/www.cybus.io\/en\/resources\/glossary\/opc-ua\/","title":{"rendered":"OPC UA"},"content":{"rendered":"<div class=\"wp-block-nb-onecol ce ce-onecol pt-large pb-large wide bgr-blue-dark bgr-img-fullwidth\" style=\"background-image:url(https:\/\/www.cybus.io\/wp-content\/uploads\/2026\/11\/cybus_sap_dm_hero_2026_1024x500.webp)\"><div class=\"container\"><div class=\"row\"><div class=\"col\">\n\n<h1 id=\"h-opc-ua-definition-information-model-and-role-in-manufacturing\" class=\"wp-block-heading is-style-hero-title\">OPC UA: Definition, Information Model and Role in Manufacturing<\/h1>\n\n<\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-nb-onecol ce ce-onecol pt-medium pb-medium wide bgr-blue-light\"><div class=\"container\"><div class=\"row\"><div class=\"col\">\n\n<h2 id=\"what-is-opc-ua\" class=\"wp-block-heading\">What is OPC UA?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>In short:<\/strong> OPC UA (Open Platform Communications Unified Architecture) is an open, vendor-independent standard for exchanging data between machines, controllers and IT systems. It transports values together with their meaning: a temperature arrives with its unit, its data type, its timestamp and its place in a model of the machine. OPC UA is maintained by the <a href=\"https:\/\/opcfoundation.org\/about\/opc-technologies\/opc-ua\/\" target=\"_blank\" rel=\"noreferrer noopener\">OPC Foundation<\/a>, published as the international standard IEC 62541 and has become the common language at the source of industrial data.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Jump to:<\/strong> <strong><a href=\"#origin\">Origin<\/a> \u00b7 <a href=\"#information-model\">How it works<\/a> \u00b7 <a href=\"#client-server-pubsub\">Client\/server and PubSub<\/a> \u00b7 <a href=\"#companion-specifications\">Companion Specifications<\/a> \u00b7 <a href=\"#opc-ua-vs-mqtt\">OPC UA vs. MQTT<\/a> \u00b7 <a href=\"#opc-ua-unified-namespace\">Unified Namespace<\/a> \u00b7 <a href=\"#challenges\">Challenges<\/a> \u00b7 <a href=\"#opc-ua-case-study\">Case study<\/a> \u00b7 <a href=\"#governance-security\">Security<\/a> \u00b7 <a href=\"#in-5-steps\">Implementation<\/a> \u00b7 <a href=\"#faq-opc-ua\">FAQ<\/a><\/strong><\/p>\n\n<\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-nb-onecol ce ce-onecol pt-medium wide\"><div class=\"container\"><div class=\"row\"><div class=\"col\">\n\n<h2 id=\"origin\" class=\"wp-block-heading\">From OPC Classic to OPC UA: a standard leaves Windows behind<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The first OPC specifications from the 1990s solved a practical problem: visualization software needed a uniform way to read values from controllers of different vendors. <a href=\"https:\/\/opcfoundation.org\/about\/opc-technologies\/opc-classic\/\" target=\"_blank\" rel=\"noreferrer noopener\">OPC Classic<\/a> was built on Microsoft&#8217;s COM\/DCOM technology and split into separate specifications for live data (DA), alarms and events (AE) and historical data (HDA). It worked well inside Windows networks, but it tied every installation to Windows and was hard to run securely across firewalls.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In 2008 the OPC Foundation released OPC UA as a platform-independent, service-oriented architecture that combines all functions of OPC Classic in one framework. Since 2011 it has also been published as the international standard IEC 62541. OPC UA runs on embedded devices, industrial PCs, servers and in the cloud, and it no longer depends on any single operating system.<\/p>\n\n\n\n<h3 id=\"opc-ua-vs-opc-da\" class=\"wp-block-heading\">OPC UA vs. OPC DA: what changed<\/h3>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout has-black-color has-text-color\" style=\"table-layout:fixed;width:100%\"><colgroup><col style=\"width:25%\"><col style=\"width:37.5%\"><col style=\"width:37.5%\"><\/colgroup><thead><tr><th style=\"text-align:left\"><\/th><th style=\"text-align:left\">OPC DA (OPC Classic)<\/th><th style=\"text-align:left\">OPC UA<\/th><\/tr><\/thead><tbody><tr><td style=\"text-align:left\"><strong>Platform<\/strong><\/td><td style=\"text-align:left\">Windows only, based on COM\/DCOM<\/td><td style=\"text-align:left\">Platform-independent, from embedded devices to the cloud<\/td><\/tr><tr><td style=\"text-align:left\"><strong>Data<\/strong><\/td><td style=\"text-align:left\">Values with timestamp and quality<\/td><td style=\"text-align:left\">Values embedded in an information model with types, units and relationships<\/td><\/tr><tr><td style=\"text-align:left\"><strong>Functions<\/strong><\/td><td style=\"text-align:left\">Separate specifications for live data, alarms and history<\/td><td style=\"text-align:left\">Live data, alarms, events, history and methods in one architecture<\/td><\/tr><tr><td style=\"text-align:left\"><strong>Security<\/strong><\/td><td style=\"text-align:left\">Depends on Windows and DCOM configuration<\/td><td style=\"text-align:left\">Built-in authentication, signing and encryption<\/td><\/tr><tr><td style=\"text-align:left\"><strong>Network<\/strong><\/td><td style=\"text-align:left\">Difficult to route through firewalls<\/td><td style=\"text-align:left\">Binary protocol over a single TCP port, HTTPS and WebSockets as alternatives<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Many plants still run OPC DA servers. They do not have to be replaced to take part in a modern data architecture, because a <a href=\"https:\/\/www.cybus.io\/en\/product\/connectivity-portfolio\/opc-da\/\">connector for OPC DA<\/a> can read them and pass the values on.<\/p>\n\n\n\n<h3 id=\"key-terms\" class=\"wp-block-heading\">Key terms<\/h3>\n\n\n\n<ul class=\"wp-block-list is-style-arrow-list\">\n<li><strong>Address space:<\/strong> the complete set of data and functions a server makes available, organized as a network of nodes.<\/li>\n\n\n\n<li><strong>Node:<\/strong> a single element in the address space, for example an object, a variable, a method or a type.<\/li>\n\n\n\n<li><strong>Information model:<\/strong> the structure that describes what the nodes mean and how they relate to each other.<\/li>\n\n\n\n<li><strong>Server and client:<\/strong> the server provides the address space, the client reads, writes, subscribes or calls methods.<\/li>\n\n\n\n<li><strong>PubSub:<\/strong> the publish\/subscribe extension of OPC UA, in which data is sent to many receivers without a session per client.<\/li>\n\n\n\n<li><strong>Companion Specification:<\/strong> a standardized information model for a type of machine or an industry.<\/li>\n\n\n\n<li><strong>NodeSet:<\/strong> an XML file that describes an information model so that tools and servers can import it.<\/li>\n<\/ul>\n\n<\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-nb-onecol ce ce-onecol pt-small wide\"><div class=\"container\"><div class=\"row\"><div class=\"col\">\n\n<h2 id=\"the-problem\" class=\"wp-block-heading\">A value without context is just a number<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A controller that reports the value 72 in register 40001 tells an IT system very little. Is it a temperature, a pressure or a counter? In degrees Celsius or Fahrenheit? Which machine, which line, which plant? In many factories this knowledge sits in the heads of a few automation engineers or in spreadsheets that map addresses to meanings. Every new application has to rebuild that mapping, and every additional line repeats the effort.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The result is a factory that looks connected from the top floor while the data still does not flow. In the <a href=\"https:\/\/hexagon.com\/company\/newsroom\/press-releases\/2026\/77-of-manufacturers-call-their-operations-connected-only-40-really-are\" target=\"_blank\" rel=\"noreferrer noopener\">State of Manufacturing Report 2026<\/a>, a survey of 511 manufacturing professionals in the United States from July 2026, 77% describe their operations as fully or mostly connected. Only 40% say they are connected across design, production, quality and business systems, and 67% do not have data from most of their systems integrated into a single view.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This gap becomes expensive as soon as a use case is meant to scale. Analytics, <a href=\"https:\/\/www.cybus.io\/en\/resources\/glossary\/industrial-ai\/\">Industrial AI<\/a> and energy management all need data that explains itself. OPC UA addresses the problem where it starts: at the machine, where the meaning of a value is still known and can be described once for every application that follows.<\/p>\n\n<\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-nb-onecol ce ce-onecol pt-small wide\"><div class=\"container\"><div class=\"row\"><div class=\"col\">\n\n<h2 id=\"information-model\" class=\"wp-block-heading\">How OPC UA works: an information model with a protocol attached<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">At the heart of every OPC UA server is its address space. It describes the machine as a network of nodes that are linked by references. Objects stand for physical or logical things, such as a machine, a spindle or a mold. Variables carry the current values, together with data type, engineering unit, timestamp and status. Methods let a client trigger functions on the machine, and types define reusable templates, so that every machine of the same kind is described the same way.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A client can browse this structure like a file system. For an injection molding machine it might find an object for the machine, below it an object for the heating zones and in there a variable for the cylinder temperature in degrees Celsius. The client does not need to know the register address, because the model tells it what the value is and where it belongs.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.cybus.io\/wp-content\/uploads\/2026\/11\/opc-ua-information-model-en-1024x683.webp\" alt=\"OPC UA information model compared with a raw register value: the same value described as an object with unit, data type and status\" class=\"wp-image-55178\" srcset=\"https:\/\/www.cybus.io\/wp-content\/uploads\/2026\/11\/opc-ua-information-model-en-1024x683.webp 1024w, https:\/\/www.cybus.io\/wp-content\/uploads\/2026\/11\/opc-ua-information-model-en-300x200.webp 300w, https:\/\/www.cybus.io\/wp-content\/uploads\/2026\/11\/opc-ua-information-model-en-768x512.webp 768w, https:\/\/www.cybus.io\/wp-content\/uploads\/2026\/11\/opc-ua-information-model-en.webp 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The services that work on this model are standardized. Clients read and write values, subscribe to changes so that the server sends new values only when they change, call methods, receive alarms and events and query historical data. On the wire, OPC UA mostly uses a compact binary protocol over TCP with the address scheme opc.tcp. HTTPS and WebSockets are defined as alternatives for environments that only allow web traffic.<\/p>\n\n<\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-nb-onecol ce ce-onecol pt-small wide\"><div class=\"container\"><div class=\"row\"><div class=\"col\">\n\n<h2 id=\"client-server-pubsub\" class=\"wp-block-heading\">Client\/server and PubSub: two ways to move the same model<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The classic way to use OPC UA is client\/server. The client opens a secure session with the server, browses the address space and sets up subscriptions. This pattern is well suited for engineering tools, SCADA systems and edge gateways that need a direct, bidirectional connection to a machine. Its limit lies in the number of connections, because every client opens its own session and every session costs resources on the server.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">That matters most on the controller itself. Servers that are embedded in a PLC share CPU and memory with the control task and therefore expose only a limited number of nodes and monitored items. Our expert article on the <a href=\"https:\/\/www.cybus.io\/en\/the-s7-1200-opc-ua-node-limit\/\">node limit of the S7-1200<\/a> shows how this plays out in practice and how to read every tag anyway.<\/p>\n\n\n\n<h3 id=\"opc-ua-pubsub\" class=\"wp-block-heading\">OPC UA PubSub<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">With <a href=\"https:\/\/reference.opcfoundation.org\/specs\/OPC-10000-14\/7.3.2\" target=\"_blank\" rel=\"noreferrer noopener\">Part 14 of the specification<\/a>, OPC UA added a publish\/subscribe model. A publisher sends its data sets without knowing who receives them, and any number of subscribers can listen. The specification defines transports over UDP for the field level as well as over MQTT and AMQP for brokers and the cloud. Messages can be encoded in a compact binary format or as JSON, which makes OPC UA semantics readable for IT systems that already work with MQTT.<\/p>\n\n\n\n<h3 id=\"opc-ua-fx\" class=\"wp-block-heading\">OPC UA FX<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">OPC UA FX (Field eXchange) extends the standard to the field level. The OPC Foundation&#8217;s Field Level Communications initiative has <a href=\"https:\/\/opcconnect.opcfoundation.org\/?p=3956\" target=\"_blank\" rel=\"noreferrer noopener\">published the first UAFX specifications<\/a>, which cover controller-to-controller communication across vendors. Controller-to-device and device-to-device communication are announced as future extensions.<\/p>\n\n<\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-nb-onecol ce ce-onecol pt-small wide\"><div class=\"container\"><div class=\"row\"><div class=\"col\">\n\n<h2 id=\"companion-specifications\" class=\"wp-block-heading\">Companion Specifications: shared vocabularies for whole industries<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The core specification defines how an information model is built. Companion Specifications define what it contains for a specific type of machine. Industry associations and working groups agree on which objects, variables and methods, for example, a machine tool, a robot or a weighing system exposes. A client that knows the Companion Specification can work with every compliant machine without vendor-specific mapping.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">According to the OPC Foundation, there are now <a href=\"https:\/\/opcfoundation.org\/news\/press-releases\/opc-foundation-advances-opc-ua-for-the-ai-era-with-companion-specifications-optimized-for-agentic-ai\/\" target=\"_blank\" rel=\"noreferrer noopener\">more than 430 Companion Specifications<\/a>. The <a href=\"https:\/\/reference.opcfoundation.org\/\" target=\"_blank\" rel=\"noreferrer noopener\">online reference<\/a> lists models for machine tools, robotics, PackML, plastics and rubber machinery, machine vision, pumps, weighing technology and many more. In April 2026 the OPC Foundation announced that it will convert all of them into formats for AI applications, such as retrieval-augmented generation and the Model Context Protocol. The same semantics that help an MES today are meant to help AI agents understand machines tomorrow.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In existing plants, the picture is more mixed. Many machines in operation implement no Companion Specification, an older version or no OPC UA at all. A data architecture therefore has to deal with both: standardized models where they exist and a consistent model of its own where they do not.<\/p>\n\n<\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-nb-onecol ce ce-onecol pt-small wide\"><div class=\"container\"><div class=\"row\"><div class=\"col\">\n\n<h2 id=\"automation-pyramid\" class=\"wp-block-heading\">OPC UA in the automation pyramid: from the controller to the enterprise<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The classic <a href=\"https:\/\/www.cybus.io\/en\/resources\/glossary\/automation-pyramid\/\">automation pyramid<\/a> stacks sensors and actuators, controllers, SCADA, MES and ERP in layers. Data travels from one level to the next, and each level talks to the one below through its own interfaces. OPC UA was designed to carry data from field devices up to enterprise systems, and in practice it is mainly used where controllers and machines hand their data to supervisory systems.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">OPC UA makes these interfaces more uniform, yet the basic pattern of the pyramid stays the same. When the MES, the energy management system, the quality application and a data lake each open their own connection to every machine, the number of point-to-point links grows with every new system. This is the reason many manufacturers combine OPC UA at the source with a central data hub above it.<\/p>\n\n<\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-nb-onecol ce ce-onecol pt-small wide\"><div class=\"container\"><div class=\"row\"><div class=\"col\">\n\n<h2 id=\"opc-ua-vs-mqtt\" class=\"wp-block-heading\">OPC UA vs. MQTT vs. Sparkplug B vs. Modbus: four protocols, four jobs<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">OPC UA is often compared with <a href=\"https:\/\/www.cybus.io\/en\/resources\/glossary\/mqtt\/\">MQTT<\/a>, Sparkplug B and Modbus. The four do different things and frequently appear in the same architecture. The table shows where each of them is strongest.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout has-black-color has-text-color\" style=\"table-layout:fixed;width:100%\"><colgroup><col style=\"width:20%\"><col style=\"width:20%\"><col style=\"width:20%\"><col style=\"width:20%\"><col style=\"width:20%\"><\/colgroup><thead><tr><th style=\"text-align:left\"><\/th><th style=\"text-align:left\">OPC UA<\/th><th style=\"text-align:left\">MQTT<\/th><th style=\"text-align:left\">Sparkplug B<\/th><th style=\"text-align:left\">Modbus<\/th><\/tr><\/thead><tbody><tr><td style=\"text-align:left\"><strong>Origin<\/strong><\/td><td style=\"text-align:left\">OPC Foundation, 2008, IEC 62541<\/td><td style=\"text-align:left\">Open standard (OASIS, ISO)<\/td><td style=\"text-align:left\">Eclipse Foundation specification on top of MQTT, ISO\/IEC 20237<\/td><td style=\"text-align:left\">Modicon, 1979<\/td><\/tr><tr><td style=\"text-align:left\"><strong>Communication<\/strong><\/td><td style=\"text-align:left\">Client\/server, PubSub as an extension<\/td><td style=\"text-align:left\">Publish\/subscribe via a broker<\/td><td style=\"text-align:left\">Publish\/subscribe via a broker with a defined topic structure<\/td><td style=\"text-align:left\">Request\/response<\/td><\/tr><tr><td style=\"text-align:left\"><strong>Data model<\/strong><\/td><td style=\"text-align:left\">Information model with types, units and relationships<\/td><td style=\"text-align:left\">None, the payload can be defined freely<\/td><td style=\"text-align:left\">Defined payload with metrics, data types and device states<\/td><td style=\"text-align:left\">Numbered registers and coils without meaning<\/td><\/tr><tr><td style=\"text-align:left\"><strong>Typical position<\/strong><\/td><td style=\"text-align:left\">At the machine and the controller<\/td><td style=\"text-align:left\">From the edge to the plant, the enterprise and the cloud<\/td><td style=\"text-align:left\">Between edge nodes and SCADA or host applications<\/td><td style=\"text-align:left\">Field devices, meters, drives and older controllers<\/td><\/tr><tr><td style=\"text-align:left\"><strong>Security<\/strong><\/td><td style=\"text-align:left\">Authentication, signing and encryption built in<\/td><td style=\"text-align:left\">TLS and authentication at the broker<\/td><td style=\"text-align:left\">Uses the security of MQTT<\/td><td style=\"text-align:left\">None in the classic protocol<\/td><\/tr><tr><td style=\"text-align:left\"><strong>Strength<\/strong><\/td><td style=\"text-align:left\">Describing machine data with semantics<\/td><td style=\"text-align:left\">Distributing data to many systems<\/td><td style=\"text-align:left\">Interoperable MQTT payloads for industrial applications<\/td><td style=\"text-align:left\">Simple and very widespread<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">In practice the protocols complement each other. <a href=\"https:\/\/modbus.org\/introduction-to-modbus\" target=\"_blank\" rel=\"noreferrer noopener\">Modbus<\/a> and native controller protocols reach older equipment, OPC UA describes modern machines with semantics and MQTT distributes the results through an <a href=\"https:\/\/www.cybus.io\/en\/resources\/glossary\/mqtt-broker\/\">MQTT broker<\/a> to every application that needs them. Sparkplug B adds shared rules for topics and payloads when many MQTT clients from different vendors have to understand each other. How MQTT itself works, including a comparison with HTTP, is explained on our MQTT page.<\/p>\n\n<\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-nb-onecol ce ce-onecol pt-small wide\"><div class=\"container\"><div class=\"row\"><div class=\"col\">\n\n<h2 id=\"opc-ua-unified-namespace\" class=\"wp-block-heading\">OPC UA in the Unified Namespace: semantics at the source, MQTT for distribution<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A <a href=\"https:\/\/www.cybus.io\/en\/resources\/glossary\/unified-namespace\/\">Unified Namespace<\/a> (UNS) is a central, event-driven data hub in which every system publishes its current state and every application finds the data it needs. In most implementations an MQTT broker forms its backbone, and the topic structure follows the ISA-95 hierarchy from enterprise and site to area, line and cell.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">OPC UA plays a clear role in this picture. It is the preferred way to read modern machines, and its information model provides exactly the context that a UNS needs: names, units, data types and the position of each value in the machine. An <a href=\"https:\/\/www.cybus.io\/en\/resources\/glossary\/edge-computing\/\">edge<\/a> layer reads the OPC UA server once, maps the nodes to the topic hierarchy and publishes the values together with their metadata. From there, any number of applications can subscribe without adding a single connection to the controller.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.cybus.io\/wp-content\/uploads\/2026\/11\/opc-ua-unified-namespace-architecture-en-1024x683.webp\" alt=\"OPC UA in a Unified Namespace: machines are read once at the edge and their data is distributed via an MQTT broker\" class=\"wp-image-55182\" srcset=\"https:\/\/www.cybus.io\/wp-content\/uploads\/2026\/11\/opc-ua-unified-namespace-architecture-en-1024x683.webp 1024w, https:\/\/www.cybus.io\/wp-content\/uploads\/2026\/11\/opc-ua-unified-namespace-architecture-en-300x200.webp 300w, https:\/\/www.cybus.io\/wp-content\/uploads\/2026\/11\/opc-ua-unified-namespace-architecture-en-768x512.webp 768w, https:\/\/www.cybus.io\/wp-content\/uploads\/2026\/11\/opc-ua-unified-namespace-architecture-en.webp 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">OPC UA PubSub over MQTT offers a standardized path for this mapping. In existing plants, the translation is usually done at the edge, because it also has to cover machines that speak only S7, Modbus or proprietary protocols.<\/p>\n\n<\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-nb-onecol ce ce-onecol pt-small wide\"><div class=\"container\"><div class=\"row\"><div class=\"col\">\n\n<h2 id=\"benefits\" class=\"wp-block-heading\">The benefits show when a use case leaves the pilot line<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">On a single line almost any interface works, because the people who built it know what each value means. The value of OPC UA becomes visible when the same use case is rolled out to the next line, the next plant or the next machine generation. A model that describes the data once spares every later project from mapping it again. The broad support behind the standard adds to this: the OPC Foundation counts <a href=\"https:\/\/opcfoundation.org\/news\/press-releases\/opc-foundation-advances-opc-ua-for-the-ai-era-with-companion-specifications-optimized-for-agentic-ai\/\" target=\"_blank\" rel=\"noreferrer noopener\">more than 1,010 member companies<\/a>.<\/p>\n\n\n\n<ul class=\"wp-block-list is-style-arrow-list\">\n<li><strong>Vendor neutrality:<\/strong> one open standard for controllers, machines and software from different manufacturers, without lock-in to a single supplier.<\/li>\n\n\n\n<li><strong>Semantics at the source:<\/strong> values arrive with units, data types and context, so applications need less custom mapping.<\/li>\n\n\n\n<li><strong>Security built in:<\/strong> authentication, signing and encryption are part of the specification.<\/li>\n\n\n\n<li><strong>Platform independence:<\/strong> the same standard runs on embedded devices, industrial PCs, servers and in the cloud.<\/li>\n\n\n\n<li><strong>Shared models:<\/strong> Companion Specifications make machines of the same type interchangeable from the point of view of the data.<\/li>\n\n\n\n<li><strong>Ready for what comes next:<\/strong> PubSub, OPC UA FX and the AI initiative of the OPC Foundation extend the standard without replacing existing installations.<\/li>\n<\/ul>\n\n<\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-nb-onecol ce ce-onecol pt-small wide\"><div class=\"container\"><div class=\"row\"><div class=\"col\">\n\n<h2 id=\"challenges\" class=\"wp-block-heading\">Where OPC UA reaches its limits in existing plants<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">OPC UA is a strong standard, but brownfield factories rarely consist only of modern machines. These are the typical stumbling blocks and how to deal with them.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout has-black-color has-text-color\" style=\"table-layout:fixed;width:100%\"><colgroup><col style=\"width:25%\"><col style=\"width:37.5%\"><col style=\"width:37.5%\"><\/colgroup><thead><tr><th style=\"text-align:left\">Challenge<\/th><th style=\"text-align:left\">What happens<\/th><th style=\"text-align:left\">How to deal with it<\/th><\/tr><\/thead><tbody><tr><td style=\"text-align:left\"><strong>Machines without OPC UA<\/strong><\/td><td style=\"text-align:left\">Many controllers in operation speak only S7, Modbus or proprietary protocols.<\/td><td style=\"text-align:left\">Read them in their native protocol and describe the data in a common model at the edge.<\/td><\/tr><tr><td style=\"text-align:left\"><strong>Limited embedded servers<\/strong><\/td><td style=\"text-align:left\">Servers inside a PLC expose only a limited number of nodes and monitored items.<\/td><td style=\"text-align:left\">Read several nodes per request, adjust sampling rates or switch to the native controller protocol.<\/td><\/tr><tr><td style=\"text-align:left\"><strong>Many client connections<\/strong><\/td><td style=\"text-align:left\">Every consuming system opens its own session and adds load to the machine.<\/td><td style=\"text-align:left\">Read each machine once and distribute the data through a broker.<\/td><\/tr><tr><td style=\"text-align:left\"><strong>Inconsistent models<\/strong><\/td><td style=\"text-align:left\">Without a Companion Specification, every vendor models its machines differently.<\/td><td style=\"text-align:left\">Map the data to a shared structure such as an ISA-95 based topic hierarchy.<\/td><\/tr><tr><td style=\"text-align:left\"><strong>Certificate management<\/strong><\/td><td style=\"text-align:left\">Every client and server needs certificates that must be trusted, distributed and renewed.<\/td><td style=\"text-align:left\">Manage certificates and trust lists centrally and plan their renewal.<\/td><\/tr><tr><td style=\"text-align:left\"><strong>Security switched off<\/strong><\/td><td style=\"text-align:left\">Security features are available but often not activated in delivered products.<\/td><td style=\"text-align:left\">Disable the security mode None in production and check every endpoint.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-nb-onecol ce ce-onecol pt-small wide\"><div class=\"container\"><div class=\"row\"><div class=\"col\">\n\n<h2 id=\"examples\" class=\"wp-block-heading\">OPC UA in practice: typical use cases in manufacturing<\/h2>\n\n\n\n<h3 id=\"example-oee\" class=\"wp-block-heading\">Machine monitoring and OEE<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Machine states, counters and cycle times are among the first values most manufacturers read via OPC UA. Because the server delivers them with clear names and data types, they can be fed into an <a href=\"https:\/\/www.cybus.io\/en\/solutions\/use-cases\/oee\/\">OEE calculation<\/a> without guessing what each register means.<\/p>\n\n\n\n<h3 id=\"example-mes\" class=\"wp-block-heading\">MES integration<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">An MES needs order data, quantities and quality values from the machines and sends recipes and job data back. OPC UA supports both directions with read, write and method calls. Companion Specifications such as the one for injection molding machines and MES define this exchange in a standardized way. More on this on our page about <a href=\"https:\/\/www.cybus.io\/en\/solutions\/use-cases\/mes-integration\/\">MES integration<\/a>.<\/p>\n\n\n\n<h3 id=\"example-energy\" class=\"wp-block-heading\">Energy monitoring in mixed machine fleets<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Energy data rarely comes from a single source. In a <a href=\"https:\/\/www.cybus.io\/en\/case-studies\/global-tool-manufacturer-reduces-energy-costs\/\">case study of a global tool manufacturer<\/a>, energy data was collected across a heterogeneous fleet via OPC UA, S7, Heidenhain and Modbus TCP and made available in real time. The full case study is available as a PDF in the next section.<\/p>\n\n\n\n<h3 id=\"example-pm-traceability\" class=\"wp-block-heading\">Predictive maintenance and traceability<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Vibration, temperature and current values from OPC UA servers form the input for <a href=\"https:\/\/www.cybus.io\/en\/solutions\/use-cases\/predictive-maintenance\/\">predictive maintenance<\/a> models. For <a href=\"https:\/\/www.cybus.io\/en\/solutions\/use-cases\/traceability\/\">traceability<\/a>, the timestamps and status information of OPC UA make it possible to link process values to individual parts and batches.<\/p>\n\n<\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-nb-twocol ce ce-twocol pt-medium pb-medium wide layout-6-1-5 bgr-blue-light\"><div class=\"container\"><div class=\"row\">\n<div class=\"wp-block-nb-column col col-custom-1\">\n\n<h2 id=\"opc-ua-case-study\" class=\"wp-block-heading\">Case study: real-time energy data from a mixed machine fleet<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/www.cybus.io\/wp-content\/uploads\/2023\/10\/Case-Study-cover.png\" alt=\"Case study PDF: energy monitoring with OPC UA, S7 and Modbus TCP in a mixed machine fleet\" class=\"wp-image-37398\" srcset=\"https:\/\/www.cybus.io\/wp-content\/uploads\/2023\/10\/Case-Study-cover.png 600w, https:\/\/www.cybus.io\/wp-content\/uploads\/2023\/10\/Case-Study-cover-300x200.png 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n\n\n\n<h3 id=\"h-how-a-global-clamping-and-automation-manufacturer-lowered-its-energy-costs\" class=\"wp-block-heading\">How a global clamping and automation manufacturer lowered its energy costs<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The manufacturer, with 3,500 employees and eight production sites, connected 120 machines across a heterogeneous fleet via OPC UA, S7, Heidenhain and Modbus TCP. Energy data is now available to all stakeholders in real time, fewer cleaning cycles reduce machine downtime and efficiency rose by 9%. Download the full case study as a PDF.<\/p>\n\n<\/div>\n\n<div class=\"wp-block-nb-column col col-custom-2\">\n<p><script charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js-eu1.hsforms.net\/forms\/embed\/v2.js\"><\/script><br \/>\n<script>\n  hbspt.forms.create({\n    region: \"eu1\",\n    portalId: \"143306915\",\n    formId: \"ff0c3f1b-4e99-44c7-85dc-cf7adb421a0c\"\n  });\n<\/script><\/p>\n\n<\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-nb-onecol ce ce-onecol pt-small wide\"><div class=\"container\"><div class=\"row\"><div class=\"col\">\n\n<h2 id=\"governance-security\" class=\"wp-block-heading\">OPC UA security: strong by design, effective only when switched on<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Security is part of the OPC UA architecture. Applications identify each other with X.509 certificates, users log in with a user name and password, a certificate or a token and each connection runs in one of three security modes: None, Sign or SignAndEncrypt. Security policies such as Basic256Sha256 define the algorithms that are used.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Germany&#8217;s Federal Office for Information Security (BSI) examined the standard in depth. In its <a href=\"https:\/\/newwebsite.opcfoundation.org\/wp-content\/uploads\/2023\/11\/BSI-OPCUA-2022-EN.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">OPC UA Security Analysis<\/a> (version 1.2, January 2022) it rates the security mechanisms of the specification as suitable for a high level of protection. At the same time, the analysis points out that many products do not activate these functions by default. The actual level of security therefore depends on configuration and implementation.<\/p>\n\n\n\n<ul class=\"wp-block-list is-style-arrow-list\">\n<li>Allow the security mode None only in test environments and use SignAndEncrypt in production.<\/li>\n\n\n\n<li>Maintain trust lists centrally and accept new certificates only after a deliberate check.<\/li>\n\n\n\n<li>Give each client only the rights it needs, for reading as well as for writing.<\/li>\n\n\n\n<li>Separate OT networks from IT and the internet and expose OPC UA endpoints only where they are needed.<\/li>\n\n\n\n<li>Keep server firmware and client software up to date.<\/li>\n<\/ul>\n\n<\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-nb-onecol ce ce-onecol pt-small wide\"><div class=\"container\"><div class=\"row\"><div class=\"col\">\n\n<h2 id=\"in-5-steps\" class=\"wp-block-heading\">Introducing OPC UA in production in five steps<\/h2>\n\n\n\n<ol class=\"wp-block-list is-style-default\">\n<li><strong>Take inventory:<\/strong> Record which machines offer an OPC UA server, in which version, with which Companion Specification and which machines speak only native protocols.<\/li>\n\n\n\n<li><strong>Check capacity and security:<\/strong> Find out how many nodes and subscriptions each server supports and which security modes are active.<\/li>\n\n\n\n<li><strong>Define the target model:<\/strong> Decide how values are named and structured, ideally along an ISA-95 hierarchy and with Companion Specifications where they exist.<\/li>\n\n\n\n<li><strong>Start with one line and one use case:<\/strong> Connect a limited scope, measure the result and learn from the gaps.<\/li>\n\n\n\n<li><strong>Scale with templates:<\/strong> Describe connections and mappings as configuration that can be versioned and rolled out to further lines and plants.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">In his expert article on the <a href=\"https:\/\/www.cybus.io\/en\/the-s7-1200-opc-ua-node-limit\/\">S7-1200 OPC UA node limit<\/a>, Dr. Diwaker Jha from Cybus shows how a dual-protocol strategy with OPC UA and native S7plus makes every tag of a controller visible without re-engineering.<\/p>\n\n<\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-nb-onecol ce ce-onecol pt-medium wide bgr-blue-light\"><div class=\"container\"><div class=\"row\"><div class=\"col\">\n\n<h2 id=\"opc-ua-with-cybus-connectware\" class=\"wp-block-heading\">OPC UA with Cybus Connectware<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.cybus.io\/en\/product\/cybus-connectware\/\">Cybus Connectware<\/a> works with OPC UA in both directions. As a client it reads OPC UA servers on machines and controllers, and as a server it makes data from other protocols available as OPC UA nodes. The values flow into a common data model and from there to every application that needs them.<\/p>\n\n\n\n<ul class=\"wp-block-list is-style-arrow-list\">\n<li><strong>OPC UA client:<\/strong> Subscriptions, read and write, batch read and batch write for several nodes in one request, method calls as well as events and alarms.<\/li>\n\n\n\n<li><strong>OPC UA server:<\/strong> Values from S7, Modbus and other sources appear as OPC UA nodes, secured with policies such as Basic256Sha256 and the mode SignAndEncrypt.<\/li>\n\n\n\n<li><strong>Native protocols where OPC UA is not enough:<\/strong> Adapters from the <a href=\"https:\/\/www.cybus.io\/en\/product\/connectivity-portfolio\/\">Connectivity Portfolio<\/a> read controllers in their own protocols, including Siemens S7plus. Controllers and PLC programs stay untouched.<\/li>\n\n\n\n<li><strong>Distribution via MQTT:<\/strong> The built-in broker CybusMQ comes as part of Cybus Connectware and makes the data available as the basis of a Unified Namespace.<\/li>\n\n\n\n<li><strong>Configuration as code:<\/strong> Connections and mappings are described in YAML files that can be versioned and rolled out to further plants.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">All details on the OPC UA connector can be found on the page <a href=\"https:\/\/www.cybus.io\/en\/product\/connectivity-portfolio\/opc-ua\/\">OPC UA in the Connectivity Portfolio<\/a>.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-primary\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.cybus.io\/en\/product\/cybus-connectware\/\">Discover Cybus Connectware<\/a><\/div>\n<\/div>\n\n<\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-nb-onecol ce ce-onecol pt-small wide centered bgr-blue-light\"><div class=\"container\"><div class=\"row\"><div class=\"col\">\n\n<p class=\"is-style-sub-headline has-black-color has-text-color has-link-color wp-elements-1 wp-block-paragraph\">trusted by<\/p>\n\n\n<style type=\"text\/css\">\r\n    #lgx_lsw_preloader_45415 {\r\n        display: flex;\r\n        align-items: center;\r\n        justify-content: center;\r\n        text-align: center;\r\n        background: #ffffff;\r\n        z-index: 9999;\r\n        position: absolute;\r\n        left: 0;\r\n        top: 0;\r\n        height: 100%;\r\n        width: 100%;\r\n    }\r\n<\/style><div id=\"lgx_logo_slider_app_45415\" class=\"lgx_logo_slider_app\">\r\n\r\n    <div id=\"lgx_lsw_preloader_45415\"\" class=\"lgx_lsw_preloader\"> <img decoding=\"async\" src=\"https:\/\/www.cybus.io\/wp-content\/plugins\/logo-slider-wp-pro\/public\/assets\/img\/loader.gif\" \/><\/div>\r\n    <div class=\"lgx_logo_slider lgx_logo_slider_pro\">\r\n        <div class=\"lgx_app_inner lgx_app_layout_carousel \">\r\n            <div class=\"lgx_app_container-fluid \">\r\n\r\n                             \r\n                <div class=\"lgx_app_content_area lgx_logo_position_top lgx_logo_info_align_center \">\r\n                    <div id=\"lgx_app_content_wrap_45415978\" class=\"lgx_app_content_wrapper  swiper lgx_logo_carousel\"   data-effect=\"slide\"  data-infinite=\"true\"  data-speed=\"4000\"  data-autoplay=\"true\"  data-delay=\"1\"  data-pause=\"true\"  data-space=\"20\"  data-nav=\"false\"  data-pagination=\"false\"  data-height=\"false\"  data-move=\"true\"  data-wheel=\"false\"  data-simulate=\"true\"  data-grab=\"true\"  data-dynamic=\"false\"  data-bullets_no=\"1\"  data-item_mobile=\"2\"  data-item_tablet=\"3\"  data-item_desk=\"4\"  data-item_large=\"5\"  data-lazy=\"false\"    >\r\n\r\n                        \r\n                        <div class=\"lgx_app_item_row  lgx_swiper_wrapper_ticker swiper-wrapper lgx_s_w_vertical_mid\"  >\r\n                            <div class=\"lgx_app_item  swiper-slide lgx_app_hover_effect_none\">\r\n    <div class=\"lgx_app_item_inner \" >\r\n                    <div class=\"lgx_app_item_figure lgx_img_hover_anim__default\">\r\n                <a class=\"lgx_app_item_link\"    href=\"javascript:void(0);\"  target=\"_self\" >\r\n                    <img decoding=\"async\" class=\"lgx_app_item_img \" src=\"https:\/\/www.cybus.io\/wp-content\/uploads\/2026\/01\/img-logo-agristo-1_150px.png\"  alt=\"Agristo\" \/>\r\n                                    <\/a>\r\n            <\/div> <!--\/\/.FIGURE -->\r\n                <div class=\"lgx_app_item_info\">\r\n                                          <\/div>\r\n\r\n        \r\n    <\/div>\r\n<\/div><div class=\"lgx_app_item  swiper-slide lgx_app_hover_effect_none\">\r\n    <div class=\"lgx_app_item_inner \" >\r\n                    <div class=\"lgx_app_item_figure lgx_img_hover_anim__default\">\r\n                <a class=\"lgx_app_item_link\"    href=\"javascript:void(0);\"  target=\"_self\" >\r\n                    <img decoding=\"async\" class=\"lgx_app_item_img \" src=\"https:\/\/www.cybus.io\/wp-content\/uploads\/2026\/01\/Blum_Logo_150px.png\"  alt=\"Blum\" \/>\r\n                                    <\/a>\r\n            <\/div> <!--\/\/.FIGURE -->\r\n                <div class=\"lgx_app_item_info\">\r\n                                          <\/div>\r\n\r\n        \r\n    <\/div>\r\n<\/div><div class=\"lgx_app_item  swiper-slide lgx_app_hover_effect_none\">\r\n    <div class=\"lgx_app_item_inner \" >\r\n                    <div class=\"lgx_app_item_figure lgx_img_hover_anim__default\">\r\n                <a class=\"lgx_app_item_link\"    href=\"javascript:void(0);\"  target=\"_self\" >\r\n                    <img decoding=\"async\" class=\"lgx_app_item_img \" src=\"https:\/\/www.cybus.io\/wp-content\/uploads\/2026\/01\/Claas-Logo.wine_.png\"  alt=\"CLAAS\" \/>\r\n                                    <\/a>\r\n            <\/div> <!--\/\/.FIGURE -->\r\n                <div class=\"lgx_app_item_info\">\r\n                                          <\/div>\r\n\r\n        \r\n    <\/div>\r\n<\/div><div class=\"lgx_app_item  swiper-slide lgx_app_hover_effect_none\">\r\n    <div class=\"lgx_app_item_inner \" >\r\n                    <div class=\"lgx_app_item_figure lgx_img_hover_anim__default\">\r\n                <a class=\"lgx_app_item_link\"    href=\"javascript:void(0);\"  target=\"_self\" >\r\n                    <img decoding=\"async\" class=\"lgx_app_item_img \" src=\"https:\/\/www.cybus.io\/wp-content\/uploads\/2024\/12\/references-teamviewer-logo-2024.png\"  alt=\"TeamViewer\" \/>\r\n                                    <\/a>\r\n            <\/div> <!--\/\/.FIGURE -->\r\n                <div class=\"lgx_app_item_info\">\r\n                                          <\/div>\r\n\r\n        \r\n    <\/div>\r\n<\/div><div class=\"lgx_app_item  swiper-slide lgx_app_hover_effect_none\">\r\n    <div class=\"lgx_app_item_inner \" >\r\n                    <div class=\"lgx_app_item_figure lgx_img_hover_anim__default\">\r\n                <a class=\"lgx_app_item_link\"    href=\"javascript:void(0);\"  target=\"_self\" >\r\n                    <img decoding=\"async\" class=\"lgx_app_item_img \" src=\"https:\/\/www.cybus.io\/wp-content\/uploads\/2025\/01\/Miele-logo-slider-2025-3.png\"  alt=\"Miele\" \/>\r\n                                    <\/a>\r\n            <\/div> <!--\/\/.FIGURE -->\r\n                <div class=\"lgx_app_item_info\">\r\n                                          <\/div>\r\n\r\n        \r\n    <\/div>\r\n<\/div><div class=\"lgx_app_item  swiper-slide lgx_app_hover_effect_none\">\r\n    <div class=\"lgx_app_item_inner \" >\r\n                    <div class=\"lgx_app_item_figure lgx_img_hover_anim__default\">\r\n                <a class=\"lgx_app_item_link\"    href=\"javascript:void(0);\"  target=\"_self\" >\r\n                    <img decoding=\"async\" class=\"lgx_app_item_img \" src=\"https:\/\/www.cybus.io\/wp-content\/uploads\/2024\/09\/cybus-partner-logo-capgemini-2024.png\"  alt=\"Capgemini\" \/>\r\n                                    <\/a>\r\n            <\/div> <!--\/\/.FIGURE -->\r\n                <div class=\"lgx_app_item_info\">\r\n                                          <\/div>\r\n\r\n        \r\n    <\/div>\r\n<\/div><div class=\"lgx_app_item  swiper-slide lgx_app_hover_effect_none\">\r\n    <div class=\"lgx_app_item_inner \" >\r\n                    <div class=\"lgx_app_item_figure lgx_img_hover_anim__default\">\r\n                <a class=\"lgx_app_item_link\"    href=\"javascript:void(0);\"  target=\"_self\" >\r\n                    <img decoding=\"async\" class=\"lgx_app_item_img \" src=\"https:\/\/www.cybus.io\/wp-content\/uploads\/2024\/09\/2024-reference-logo-industrialcloud.webp\"  alt=\"Industrial Cloud\" \/>\r\n                                    <\/a>\r\n            <\/div> <!--\/\/.FIGURE -->\r\n                <div class=\"lgx_app_item_info\">\r\n                                          <\/div>\r\n\r\n        \r\n    <\/div>\r\n<\/div><div class=\"lgx_app_item  swiper-slide lgx_app_hover_effect_none\">\r\n    <div class=\"lgx_app_item_inner \" >\r\n                    <div class=\"lgx_app_item_figure lgx_img_hover_anim__default\">\r\n                <a class=\"lgx_app_item_link\"    href=\"javascript:void(0);\"  target=\"_self\" >\r\n                    <img decoding=\"async\" class=\"lgx_app_item_img \" src=\"https:\/\/www.cybus.io\/wp-content\/uploads\/2024\/12\/references-liebherr-logo-2024.png\"  alt=\"Liebherr\" \/>\r\n                                    <\/a>\r\n            <\/div> <!--\/\/.FIGURE -->\r\n                <div class=\"lgx_app_item_info\">\r\n                                          <\/div>\r\n\r\n        \r\n    <\/div>\r\n<\/div><div class=\"lgx_app_item  swiper-slide lgx_app_hover_effect_none\">\r\n    <div class=\"lgx_app_item_inner \" >\r\n                    <div class=\"lgx_app_item_figure lgx_img_hover_anim__default\">\r\n                <a class=\"lgx_app_item_link\"    href=\"javascript:void(0);\"  target=\"_self\" >\r\n                    <img decoding=\"async\" class=\"lgx_app_item_img \" src=\"https:\/\/www.cybus.io\/wp-content\/uploads\/2024\/09\/2024-reference-logo-porsche.webp\"  alt=\"Porsche\" \/>\r\n                                    <\/a>\r\n            <\/div> <!--\/\/.FIGURE -->\r\n                <div class=\"lgx_app_item_info\">\r\n                                          <\/div>\r\n\r\n        \r\n    <\/div>\r\n<\/div><div class=\"lgx_app_item  swiper-slide lgx_app_hover_effect_none\">\r\n    <div class=\"lgx_app_item_inner \" >\r\n                    <div class=\"lgx_app_item_figure lgx_img_hover_anim__default\">\r\n                <a class=\"lgx_app_item_link\"    href=\"javascript:void(0);\"  target=\"_self\" >\r\n                    <img decoding=\"async\" class=\"lgx_app_item_img \" src=\"https:\/\/www.cybus.io\/wp-content\/uploads\/2024\/12\/references-krone-logo-2024.png\"  alt=\"Krone\" \/>\r\n                                    <\/a>\r\n            <\/div> <!--\/\/.FIGURE -->\r\n                <div class=\"lgx_app_item_info\">\r\n                                          <\/div>\r\n\r\n        \r\n    <\/div>\r\n<\/div>                        <\/div> <!--\/\/.APP CONTENT INNER END-->\r\n\r\n                        \r\n                                        \r\n                    <\/div> <!-- \/\/.CONTENT WRAP END-->\r\n                \r\n                \r\n            <\/div> <!-- \/\/.CONTENT AREA END-->\r\n\r\n            <\/div><!--\/\/.APP CONTAINER END-->\r\n        <\/div> <!--\/\/.INNER END-->\r\n    <\/div> <!-- APP CONTAINER END -->\r\n\r\n<\/div> <!--\/\/.APP END-->\n\n<\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-nb-onecol ce ce-onecol pt-small wide\"><div class=\"container\"><div class=\"row\"><div class=\"col\">\n\n<h2 id=\"faq-opc-ua\" class=\"wp-block-heading\">FAQ: frequently asked questions about OPC UA<\/h2>\n\n\n\n<div style=\"height:24px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 id=\"faq-1\" class=\"wp-block-heading\">What does OPC UA stand for?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Open Platform Communications Unified Architecture. The term OPC goes back to the first specifications from the 1990s, which were based on Microsoft technology. Unified Architecture refers to the combination of all earlier OPC functions in one platform-independent framework.<\/p>\n\n\n\n<h3 id=\"faq-2\" class=\"wp-block-heading\">Is OPC UA a protocol?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">OPC UA is more than a transport protocol. It is a framework that combines an information model, standardized services and several transport mappings. The binary protocol over TCP is the most common of these mappings.<\/p>\n\n\n\n<h3 id=\"faq-3\" class=\"wp-block-heading\">What is the difference between OPC UA and OPC DA?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">OPC DA is part of OPC Classic, runs only on Windows and transports values with timestamp and quality. OPC UA is platform-independent, describes data in an information model and brings its own security mechanisms.<\/p>\n\n\n\n<h3 id=\"faq-4\" class=\"wp-block-heading\">Which port does OPC UA use?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The default port for OPC UA over TCP is 4840. Servers can be configured to use other ports, and OPC UA over HTTPS or WebSockets usually runs on port 443.<\/p>\n\n\n\n<h3 id=\"faq-5\" class=\"wp-block-heading\">What is an OPC UA server and what is an OPC UA client?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The server provides the address space of a machine or system with its data and functions. The client connects to the server and reads, writes, subscribes to values or calls methods. Many systems act as both.<\/p>\n\n\n\n<h3 id=\"faq-6\" class=\"wp-block-heading\">Does OPC UA replace MQTT?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The two protocols complement each other. OPC UA describes data with semantics at the machine, MQTT distributes data efficiently to many applications. OPC UA PubSub can also use MQTT as its transport.<\/p>\n\n\n\n<h3 id=\"faq-7\" class=\"wp-block-heading\">What is OPC UA PubSub?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PubSub is the publish\/subscribe extension defined in Part 14 of the specification. Publishers send data sets to a network or broker without a session per receiver, either over UDP or over MQTT and AMQP.<\/p>\n\n\n\n<h3 id=\"faq-8\" class=\"wp-block-heading\">What is a Companion Specification?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A Companion Specification is a standardized information model for a type of machine or an industry, for example machine tools, robots or injection molding machines. According to the OPC Foundation, more than 430 of them exist.<\/p>\n\n\n\n<h3 id=\"faq-9\" class=\"wp-block-heading\">Is OPC UA secure?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The specification provides authentication with certificates, signing and encryption. The BSI rates these mechanisms as suitable for a high level of protection. In practice, security depends on activating and configuring them correctly.<\/p>\n\n\n\n<h3 id=\"faq-10\" class=\"wp-block-heading\">What role does OPC UA play in a Unified Namespace?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">OPC UA is usually the source connection. Its information model supplies names, units and structure, which an edge layer maps into the topic hierarchy of the Unified Namespace and publishes via MQTT.<\/p>\n\n<\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-nb-onecol ce ce-onecol pt-small pb-small wide\"><div class=\"container\"><div class=\"row\"><div class=\"col\">\n\n<h2 id=\"further-reading\" class=\"wp-block-heading\">Further reading on OPC UA and industrial connectivity<\/h2>\n\n\n\n<ul class=\"wp-block-list is-style-arrow-list\">\n<li><strong>Glossary:<\/strong> <a href=\"https:\/\/www.cybus.io\/en\/resources\/glossary\/mqtt\/\">MQTT: definition, how it works and its role in manufacturing<\/a><\/li>\n\n\n\n<li><strong>Glossary:<\/strong> <a href=\"https:\/\/www.cybus.io\/en\/resources\/glossary\/mqtt-broker\/\">MQTT broker: definition, architecture and selection criteria<\/a><\/li>\n\n\n\n<li><strong>Glossary:<\/strong> <a href=\"https:\/\/www.cybus.io\/en\/resources\/glossary\/unified-namespace\/\">Unified Namespace: definition, architecture and implementation<\/a><\/li>\n\n\n\n<li><strong>Article:<\/strong> <a href=\"https:\/\/www.cybus.io\/en\/the-s7-1200-opc-ua-node-limit\/\">The S7-1200 OPC UA Node Limit: Breaking the Built-In Server Ceiling in Siemens Controllers<\/a><\/li>\n<\/ul>\n\n<\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-nb-onecol ce ce-onecol pt-large pb-large wide centered bgr-blue-dark bgr-img-fullwidth\" style=\"background-image:url(https:\/\/www.cybus.io\/wp-content\/uploads\/2024\/03\/Hero-banner-webinar-energy-efficiency-in-manufacturing.jpg)\"><div class=\"container\"><div class=\"row\"><div class=\"col\">\n\n<h2 id=\"cta-opc-ua\" class=\"wp-block-heading is-style-default\">Connecting OPC UA machines to your data platform?<\/h2>\n\n\n\n<h3 id=\"cta-subline\" class=\"wp-block-heading is-style-default\">Talk to our experts about your data architecture.<\/h3>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-primary\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.cybus.io\/en\/contact\/\">Get in touch<\/a><\/div>\n<\/div>\n\n<\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"","protected":false},"author":5,"featured_media":36518,"parent":31308,"menu_order":25,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-20771","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>OPC UA Protocol: Definition, Use Cases &amp; Examples<\/title>\n<meta name=\"description\" content=\"What is OPC UA? How the open standard describes machine data, how it compares to MQTT and what role it plays in a Unified Namespace.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.cybus.io\/en\/resources\/glossary\/opc-ua\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"OPC UA Protocol: Definition, Use Cases &amp; Examples\" \/>\n<meta property=\"og:description\" content=\"What is OPC UA? How the open standard describes machine data, how it compares to MQTT and what role it plays in a Unified Namespace.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.cybus.io\/en\/resources\/glossary\/opc-ua\/\" \/>\n<meta property=\"og:site_name\" content=\"Cybus.io\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/cybusgmbh\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-18T19:14:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.cybus.io\/wp-content\/uploads\/2023\/09\/iiot-glossary-thumbnail.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"627\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"OPC UA\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.cybus.io\\\/en\\\/resources\\\/glossary\\\/opc-ua\\\/\",\"url\":\"https:\\\/\\\/www.cybus.io\\\/en\\\/resources\\\/glossary\\\/opc-ua\\\/\",\"name\":\"OPC UA Protocol: Definition, Use Cases & Examples\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.cybus.io\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.cybus.io\\\/en\\\/resources\\\/glossary\\\/opc-ua\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.cybus.io\\\/en\\\/resources\\\/glossary\\\/opc-ua\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.cybus.io\\\/wp-content\\\/uploads\\\/2023\\\/09\\\/iiot-glossary-thumbnail.jpg\",\"datePublished\":\"2023-09-22T12:25:39+00:00\",\"dateModified\":\"2026-11-18T19:14:39+00:00\",\"description\":\"What is OPC UA? How the open standard describes machine data, how it compares to MQTT and what role it plays in a Unified Namespace.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.cybus.io\\\/en\\\/resources\\\/glossary\\\/opc-ua\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.cybus.io\\\/en\\\/resources\\\/glossary\\\/opc-ua\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.cybus.io\\\/en\\\/resources\\\/glossary\\\/opc-ua\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.cybus.io\\\/wp-content\\\/uploads\\\/2023\\\/09\\\/iiot-glossary-thumbnail.jpg\",\"contentUrl\":\"https:\\\/\\\/www.cybus.io\\\/wp-content\\\/uploads\\\/2023\\\/09\\\/iiot-glossary-thumbnail.jpg\",\"width\":1200,\"height\":627},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.cybus.io\\\/en\\\/resources\\\/glossary\\\/opc-ua\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.cybus.io\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Resources\",\"item\":\"https:\\\/\\\/www.cybus.io\\\/en\\\/resources\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Glossary\",\"item\":\"https:\\\/\\\/www.cybus.io\\\/en\\\/resources\\\/glossary\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"OPC UA\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.cybus.io\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.cybus.io\\\/en\\\/\",\"name\":\"Cybus.io\",\"description\":\"Real-time data flow for the Manufacturing Industry\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.cybus.io\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.cybus.io\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.cybus.io\\\/en\\\/#organization\",\"name\":\"Cybus GmbH\",\"alternateName\":\"Cybus\",\"url\":\"https:\\\/\\\/www.cybus.io\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.cybus.io\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.cybus.io\\\/wp-content\\\/uploads\\\/2022\\\/03\\\/cropped-cybus-logo-bildmarke300x290.png\",\"contentUrl\":\"https:\\\/\\\/www.cybus.io\\\/wp-content\\\/uploads\\\/2022\\\/03\\\/cropped-cybus-logo-bildmarke300x290.png\",\"width\":512,\"height\":512,\"caption\":\"Cybus GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/www.cybus.io\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/cybusgmbh\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/cybus\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCkp33a41zYUZ1QwilQtfAUQ\"],\"description\":\"Das Softwareunternehmen Cybus hat sich auf die Datenintegration und Datenmanagement f\u00fcr gro\u00dfe Produktionsumgebungen spezialisiert. Der Factory Data Hub Connectware sammelt, verarbeitet und verteilt industrielle Daten und erm\u00f6glicht eine nahtlose Kommunikation zwischen heterogenen Produktions- und Cloud-Systemen. Sie unterst\u00fctzt eine skalierbare und einheitliche Architektur auf globaler Ebene, entlang mehrerer Fabrikstandorte und ist auf produktionskritische Abl\u00e4ufe zugeschnitten. Mit Cybus verbessern global agierende Unternehmen wie Liebherr, Porsche und Blum die Effizienz und Nachhaltigkeit ihrer Produktionsprozesse.\",\"email\":\"hello@cybus.io\",\"telephone\":\"+4940228586850\",\"legalName\":\"Cybus GmbH\",\"foundingDate\":\"2015-03-31\",\"vatID\":\"DE300254627\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"51\",\"maxValue\":\"200\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"OPC UA Protocol: Definition, Use Cases & Examples","description":"What is OPC UA? How the open standard describes machine data, how it compares to MQTT and what role it plays in a Unified Namespace.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.cybus.io\/en\/resources\/glossary\/opc-ua\/","og_locale":"en_US","og_type":"article","og_title":"OPC UA Protocol: Definition, Use Cases & Examples","og_description":"What is OPC UA? How the open standard describes machine data, how it compares to MQTT and what role it plays in a Unified Namespace.","og_url":"https:\/\/www.cybus.io\/en\/resources\/glossary\/opc-ua\/","og_site_name":"Cybus.io","article_publisher":"https:\/\/www.facebook.com\/cybusgmbh\/","article_modified_time":"2026-11-18T19:14:39+00:00","og_image":[{"width":1200,"height":627,"url":"https:\/\/www.cybus.io\/wp-content\/uploads\/2023\/09\/iiot-glossary-thumbnail.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_title":"OPC UA","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.cybus.io\/en\/resources\/glossary\/opc-ua\/","url":"https:\/\/www.cybus.io\/en\/resources\/glossary\/opc-ua\/","name":"OPC UA Protocol: Definition, Use Cases & Examples","isPartOf":{"@id":"https:\/\/www.cybus.io\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.cybus.io\/en\/resources\/glossary\/opc-ua\/#primaryimage"},"image":{"@id":"https:\/\/www.cybus.io\/en\/resources\/glossary\/opc-ua\/#primaryimage"},"thumbnailUrl":"https:\/\/www.cybus.io\/wp-content\/uploads\/2023\/09\/iiot-glossary-thumbnail.jpg","datePublished":"2023-09-22T12:25:39+00:00","dateModified":"2026-11-18T19:14:39+00:00","description":"What is OPC UA? How the open standard describes machine data, how it compares to MQTT and what role it plays in a Unified Namespace.","breadcrumb":{"@id":"https:\/\/www.cybus.io\/en\/resources\/glossary\/opc-ua\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.cybus.io\/en\/resources\/glossary\/opc-ua\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.cybus.io\/en\/resources\/glossary\/opc-ua\/#primaryimage","url":"https:\/\/www.cybus.io\/wp-content\/uploads\/2023\/09\/iiot-glossary-thumbnail.jpg","contentUrl":"https:\/\/www.cybus.io\/wp-content\/uploads\/2023\/09\/iiot-glossary-thumbnail.jpg","width":1200,"height":627},{"@type":"BreadcrumbList","@id":"https:\/\/www.cybus.io\/en\/resources\/glossary\/opc-ua\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.cybus.io\/en\/"},{"@type":"ListItem","position":2,"name":"Resources","item":"https:\/\/www.cybus.io\/en\/resources\/"},{"@type":"ListItem","position":3,"name":"Glossary","item":"https:\/\/www.cybus.io\/en\/resources\/glossary\/"},{"@type":"ListItem","position":4,"name":"OPC UA"}]},{"@type":"WebSite","@id":"https:\/\/www.cybus.io\/en\/#website","url":"https:\/\/www.cybus.io\/en\/","name":"Cybus.io","description":"Real-time data flow for the Manufacturing Industry","publisher":{"@id":"https:\/\/www.cybus.io\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.cybus.io\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.cybus.io\/en\/#organization","name":"Cybus GmbH","alternateName":"Cybus","url":"https:\/\/www.cybus.io\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.cybus.io\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.cybus.io\/wp-content\/uploads\/2022\/03\/cropped-cybus-logo-bildmarke300x290.png","contentUrl":"https:\/\/www.cybus.io\/wp-content\/uploads\/2022\/03\/cropped-cybus-logo-bildmarke300x290.png","width":512,"height":512,"caption":"Cybus GmbH"},"image":{"@id":"https:\/\/www.cybus.io\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/cybusgmbh\/","https:\/\/www.linkedin.com\/company\/cybus\/","https:\/\/www.youtube.com\/channel\/UCkp33a41zYUZ1QwilQtfAUQ"],"description":"Das Softwareunternehmen Cybus hat sich auf die Datenintegration und Datenmanagement f\u00fcr gro\u00dfe Produktionsumgebungen spezialisiert. Der Factory Data Hub Connectware sammelt, verarbeitet und verteilt industrielle Daten und erm\u00f6glicht eine nahtlose Kommunikation zwischen heterogenen Produktions- und Cloud-Systemen. Sie unterst\u00fctzt eine skalierbare und einheitliche Architektur auf globaler Ebene, entlang mehrerer Fabrikstandorte und ist auf produktionskritische Abl\u00e4ufe zugeschnitten. Mit Cybus verbessern global agierende Unternehmen wie Liebherr, Porsche und Blum die Effizienz und Nachhaltigkeit ihrer Produktionsprozesse.","email":"hello@cybus.io","telephone":"+4940228586850","legalName":"Cybus GmbH","foundingDate":"2015-03-31","vatID":"DE300254627","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"51","maxValue":"200"}}]}},"_links":{"self":[{"href":"https:\/\/www.cybus.io\/en\/wp-json\/wp\/v2\/pages\/20771","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.cybus.io\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.cybus.io\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.cybus.io\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.cybus.io\/en\/wp-json\/wp\/v2\/comments?post=20771"}],"version-history":[{"count":3,"href":"https:\/\/www.cybus.io\/en\/wp-json\/wp\/v2\/pages\/20771\/revisions"}],"predecessor-version":[{"id":55186,"href":"https:\/\/www.cybus.io\/en\/wp-json\/wp\/v2\/pages\/20771\/revisions\/55186"}],"up":[{"embeddable":true,"href":"https:\/\/www.cybus.io\/en\/wp-json\/wp\/v2\/pages\/31308"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.cybus.io\/en\/wp-json\/wp\/v2\/media\/36518"}],"wp:attachment":[{"href":"https:\/\/www.cybus.io\/en\/wp-json\/wp\/v2\/media?parent=20771"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}